It is no surprise that Johannesburg, Tshwane and Cape Town all have less than ten years of useful landfill life left, as waste management is the least prioritised municipal service in most South African municipalities.
It lags significantly behind housing, water, electricity, and road infrastructure. South Africa’s eight Category ‘A’ metropolitan municipalities have the highest population numbers and therefore generate the largest waste volumes, at about 20 million and 10 million tons of waste a year respectively, of which the bulk is landfilled. Landfilling at an average density of 1 t/m3 means that municipalities need an annual landfill space of about 10 million m3. With landfill space at such a premium, the controlled, planned, and systematic filling of landfill cells requires progressive closure and rehabilitation. The recent fire at the New England Road landfill in Pietermaritzburg, KwaZulu-Natal has raised awareness about the myriad issues facing the proper management of such sites throughout South Africa. In terms of landfill assessments, infrastructure consulting firm AECOM’s integrated approach allows it to assist throughout the landfill lifecycle, from site identification and landfill design to rehabilitation and closure planning. A key component of landfill management is also regulatory. In this case, AECOM provides advisory services as well as technical expertise to ensure legal compliance related to waste management and water use. “We like to engage with the client as opposed to just adopting an off-the-shelf approach. We adopt a needs analysis as opposed to a tick-box approach. Viability is critical, as we need to consider the actual budget and capability of the client so as to determine the best phased approach possible,” explains Elisabeth Nortje (Pri.Sci.Nat.), Market Sector Lead – Environment, Africa. The regulatory aspect is critical, especially due to a large number of unlicensed landfill sites in South Africa. It takes at least nine to 12 months to obtain environmental approval, in addition to all of the supporting specialist technical studies that are required. Therefore, the critical pathway of any landfill project is quite often the authorisation component. “Many municipalities are really struggling to get this right. In addition, we also have so many unlicensed landfill sites. This is a historic problem, given that many are quite old and started operating well before the latest environmental legislation came into effect,” highlights Nortje. Landfills may need to be closed for various reasons, including unacceptable environmental impacts such as groundwater pollution, and/or unmanageable air pollution such as dust or odours. Geological issues include dolomitic ground conditions, which can result in water ingress and sinkhole formation. In many instances, improving landfill management and operations is a necessary first step, but if this proves unsuccessful, closure becomes necessary. The process of landfill closure and remediation is legislated by the National Environmental Management Waste Act (NEMWA), the Water Act and the Waste Management Series. While it might seem that the closure process only commenced once the landfill has reached the end of its useful life, there are factors that can need to be attended to while the site is still operational. The slopes of the waste body must be resolved to ensure they lie at a safe angle. This should be maintained throughout the operational phase, after which capping is carried out by means of an engineered liner. Furthermore, all stormwater run-off must be diverted away from the waste body so as to separate the clean and dirty water circuits, and to prevent leachate soaking into the waste body, which can result in subsequent groundwater pollution and odours. The site must also be fully secured and access-controlled to prevent trespassers. For example, there could be an issue with people remining the waste body for recyclables, which presents a fire risk, as well as allowing rainwater to permeate the waste body. Following closure and remediation, the landfill site is subject to a recommended post-closure monitoring period of up to 30 years. This is to monitor the integrity of the capping and the impact of the quality of the groundwater quality in and around the waste body. There may also be a need for ongoing pumping and treatment of the leachate that gathers in the leachate collection system. The landfill will also most likely require a methane management system, whether by landfill gas harvesting or regular flaring, so as to prevent methane build-up, fire risk and air pollution. *Press Release by AECOM AECOM is the world’s trusted infrastructure consulting firm, delivering professional services throughout the project lifecycle – from planning, design and engineering to programme and construction management.What else to read
Additional Reading?
Request Free CopyRelated Articles
Jul 10, 2024
Eskom marks 100 days of no load shedding
State power utility Eskom has reached 100 days without implementing load shedding for the first time since 2020. “Considering the Intensity and the levels of load shedding in 2023, the ability to get to 100 days without load shedding is...
Nov 29, 2023
Water for a Thirsty Land: new book commemorates SA’s largest civil engineering project – 50 years on
In 1973, South Africa’s largest and most complex civil engineering project undertaken to date was officially opened. In recognition of the 50th anniversary of the momentous occasion of the opening of the Gariep Dam, the South African Institution of...
Oct 23, 2024
Minister Majodina Applauds Umngeni-Uthukela Water On AA+ Credit Rating
The Minister of Water and Sanitation, Ms Pemmy Majodina, has commended uMngeni-uThukela Water for its recent positive AA+ rating by Fitch Ratings, attributing this significant achievement to prudent financial management and strong leadership at the...